GB
19
Electrical connection
The electrical connection of the hob and any built-in
oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.
Terminal board
On the lower part of the
appliance there is a connection
box for the different types of
electricity supply (the picture is
only an indication and is not an
exact representation of the
purchased model).
Single-phase connection
The cable provided should only be used for this type of
installation.
Mains supply characteristics:
Voltage and mains frequency
230/240V 1+N ~ 50 Hz
230V 2 ~ 50 Hz
If the hob has a supply cable fitted,
connect it to the mains, using the
colours as a guide (see diagram).
If the hob does not have a supply cable fitted, proceed
as follows:
1. Use the supply cable provided (where applicable)
or a suitable supply cable, H05VV-F or higher, with
the right dimensions (cable section: 2.5 mm).
2. To open the terminal board, insert a screwdriver
into the side tabs of the cover (see Terminal board
picture).
3. The terminal board is designed for single-phase
connection: make sure the connection supports
between springs 1 and 2 and those between 4 and
5 are in the right position (see Single-phase
picture).
4. Position the wires according to the following
diagram and table and connect the appliance by
tightening all the screws for the springs as much as
possible.
Voltage and
mains
frequency
Electrical connections
Terminal
board
230/240V 1+N ~
50 Hz
230V 2 ~ 50 Hz
Single-
phase
Single-phase
5. Secure the power supply cable by fastening the
clamp screw and put the cover back on.
UNDERSIDE OF HOB
LN
12345
Blue
Brown
N
Neutral
L
Live
Green/Yellow
Earth
5
1
2
3
4
U-bolt
connection support
Phase Neutral Earth
Kommentare zu diesen Handbüchern