Whirlpool ADN 103 Bedienungsanleitung Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
22
Safety pressostat
Start up timer
This timer delays start up for 2-
3 minutes after machine is switched on. This delay allows ice
formed on evaporator to partially melt. When the machine restarts ice will be wet and loose in
evaporator, and hence gearbox/auger breakage risk is reduced.
THIS TIMER ONLY WORKS WHEN MACHINE IS WARM.
Safety devices.
Overload protection device: will trip if maximum current intensity (A) is exceeded, hence
preventing the motor from overheating due to current peaks. When overload trip
s, a red light
will switch on in the front panel. The overload must be reset manually, to do so the front grille
and overload cover must be removed.
Thermal protection device: will trip if temperature in motor exceeds set point. When this
device trips, the same red light will switch on in the front panel. In this case, however, reset is
automatic.
Low water level sensor: a magnetically activated sensor (buoy) located inside the water
trough will switch off the machine should the level of water fall below the set minimum. A red
light will switch on in the front panel labelled low water level. Reset is automatic.
Bin full of ice: a micro-switch located at the top of the evaporator will stop the machine when
the bin (and the ice discharge tube leading to th
e bin) is full of ice. An orange light will switch
on in the front panel labelled bin full. Reset is automatic.
This safety device trips when pressure is too
high. Pressure might reach
the set limit of 27 Kg/cm2 when:
a)
Air circulation is not sufficient, room temperature is too high, condenser
is dirty or fan motor is broken. (air-cooled models)
b
) Insufficient water in the cooling circuit, inlet water temperature is too high
or fan motor is broken (water -cooled models).
The safety pressostat will switch off the machine completely until pressure
drops again to its lower set point value (21 Kg/cm2)
HIGH PRESSURE SET POINTS (non-adjustable):
27-21 Kg/cm2 (380-296 Psi.)
Seitenansicht 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 32 33

Kommentare zu diesen Handbüchern

Keine Kommentare