DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: if the distance “A” between the wall cabinets is between 600 mm
and 730 mm, the height “B” must be a minimum of 530 mm.
If the distance “A” between the wall cabinets is greater than the width of
the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.
INJECTORS TABLE
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
Rapid 128B 3.00 286 l/h0.800.60
17 20 25Semi-rapid 95 1.65 157 l/h0.450.35
Auxiliary78A 1.00 95 l/h0.350.30
NATURAL GAS
(Methane) G25
Rapid 128B 3.00 332 l/h0.60
20 25 30Semi-rapid 95 1.65 183 l/h0.35
Auxiliary78A 1.00 111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid 87 3.00 218 g/h0.60
20 28-30 35Semi-rapid 67 1.65 120 g/h0.35
Auxiliary501.0073 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid 87 3.00 214 g/h0.60
25 37 45Semi-rapid 67 1.65 118 g/h0.35
Auxiliary501.0071 g/h0.30
Type of gas used Model
conguration
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar1 R - 2 SR - 1 AUX 7.30 695 l/
.52
G25 25 mbar1 R - 2 SR - 1 AUX 7.30 809 l/
.187
G30 28-30 mbar1 R - 2 SR - 1 AUX 7.30 531 g/h 30.94
G31 37 mbar1 R - 2 SR - 1 AUX 7.30 521 g/h 23.80
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz