DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: in case of installation of a hood above the cooktop, please refer
to the hood instructions for the correct distance.
INJECTORS TABLE
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Rapid128 3.00 286 l/h0.60
17 20 25
Semi-rapid 95 1.65 157 l/h0.35
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Rapid873.00218 g/h0.60
25 30 35
Semi-rapid 67 1.65 120 g/h0.35
Type of gas used Model
conguration
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 2 burners4.65443 l/
.52
G30/G31 30 mbar 2 burners4.65338 g/h 30.94
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz - 0,6W