INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGES
with standard clean oven
Table of Contents
RANGE SAFETY .............................................................................2
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................4
Electrical Requirements ...............................................................5
Gas Supply Requirements...........................................................6
INSTALLATION INSTRUCTIONS..................................................7
Unpack Range..............................................................................7
Install Anti-Tip Bracket.................................................................7
Make Gas Connection .................................................................8
Verify Anti-Tip Bracket Is Installed and Engaged ......................10
Level Range................................................................................10
Electronic Ignition System .........................................................10
Complete Installation .................................................................12
GAS CONVERSIONS....................................................................12
LP Gas Conversion ....................................................................12
Complete Conversion ................................................................14
Natural Gas Conversion.............................................................15
Complete Conversion ................................................................16
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
W10477538B
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS30" (76.2 CM) FREESTANDING GAS RANGESwith standard clean ovenTable of ContentsRANGE SAFETY ...

Seite 2 - RANGE SAFETY

10Verify Anti-Tip Bracket Is Installed and Engaged1. Place the outside of your foot against the bottom front of the broiler, and grasp the lower right

Seite 3 - INSTALLATION REQUIREMENTS

114. Check each cooktop burner for proper flame. The small inner cone should have a very distinct blue flame ¼" (0.64 cm) to ½" (0.13 cm) lo

Seite 4 - Product Dimensions

12Complete Installation1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.2

Seite 5 - Cabinet Dimensions

133. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.IMPORTAN

Seite 6 - Gas Pressure Regulator

14For models with 4 standard burners:For models with 3 standard burners and 1 super burner:5. Place the Natural gas orifice spuds in the parts bag for

Seite 7

15Natural Gas ConversionTo Convert Gas Pressure Regulator1. Turn manual shutoff valve to the “closed” position.2. Unplug range or disconnect power.3.

Seite 8 - Typical rigid pipe connection

4. Install the Natural gas orifice spuds using a 7 mm combination wrench. NOTE: Depending on model, the range cooktop may be equipped with 4 standard

Seite 9 - Complete Connection

2RANGE SAFETYYou can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don'tfollow All

Seite 10

3INSTALLATION REQUIREMENTSTools and PartsGather the required tools and parts before starting installation. Read and follow the instructions provided w

Seite 11 - If the flame needs adjusting:

4Location RequirementsIMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air. It is the insta

Seite 12 - GAS CONVERSIONS

5Cabinet DimensionsCabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and36" (91

Seite 13 - To Convert Surface Burners

6Gas Supply RequirementsObserve all governing codes and ordinances. IMPORTANT: This installation must conform with all local codes and ordinances. In

Seite 14 - To Convert Oven Burner

7Burner Input RequirementsInput ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m). For elevations above 2,000

Seite 15

83. Determine and mark centerline of the cutout space. The mounting can be installed on either the left side or right side of the cutout. Position mou

Seite 16

9Typical flexible connection1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters (see B