Whirlpool AMD 064 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Split-System-Klimaanlagen Whirlpool AMD 064 herunter. Whirlpool AMD 064 Instruction for Use [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
25
PRECAUTIONS FOR USE
Warning:
Make sure to insert the power plug securely.
Insecure insertion of the plug may cause
electrocution or fire.
Never unplug the machine while running.
Do not damage the cord or use an unapproved
cord.
Do not plug other electric appliances into the
same socket or use extension cords.
Never operate the air conditioner with wet
hands.
Do not pull the plug out by the cord. This could
cause the cord to overheat and catch fire.
Turn off the air conditioner and pull out the plug
when cleaning the air conditioner. This will
prevent electrocution or injury.
The rated voltage of this air conditioner is 220-
240V with a tolerance of ±22V for fluctuation.
The compressor will vibrate if the voltage is too
low, causing damage to the cooling system.
If you notice anything unusual (e.g. burnt smell),
switch off the power supply immediately and
contact the Whirlpool Authorized Service
Center nearest you.
If the abnormal condition continues, the air
conditioner could be damaged and could also
cause electrocution or fire.
Grounding: The unit must be reliably grounded.
The grounding cable must be connected to the
special grounding system in the building.
If the building does not have a grounding
system, ask an expert electrician to install one.
Never connect the grounding cable to a gas
pipe, water pipe, sewage pipe or other unless
the professional considers it reliable.
Make sure to unplug air conditioner when not in
use for an extended period. Accumulation of
dust could cause heating or fire.
Set the room temperature appropriately. The
difference between indoor and outdoor
temperature should be 5°C.
Appropriate adjustment of the temperature
setting serves to reduce consumption.
When the air conditioner is running, do not
leave doors and windows open in the room.
This will prevent loss of effectiveness of the air
conditioner.
Never block the air inlet or outlet of indoor and
outdoor unit, as this will decrease the effect of
the air conditioner or cause it to shut down or
even catch fire.
Spray cans, chemicals and gas tanks must be
placed at least 1m away from the indoor and
outdoor unit; they could cause fire or explosion
Make sure to mount the outdoor unit on a
sturdy base. If the base is damaged and
unsteady, the unit could fall and cause injury.
Do not stand or place anything on the outdoor
unit. Persons or objects falling from the unit
could cause injuries.
Do not repair the air conditioner yourself.
Incorrect repairs could cause electrocution or
fire. Contact the Whirlpool Authorized Service
Center nearest you for repairs.
Adjust the air flow and direction properly. When
the air conditioner is running, you can adjust the
air flow direction by setting the upper/lower
guide louver position using the remote control
or handle.
Never reach with your finger or a stick into the
indoor or outdoor unit.
Never blow the air directly at pets or plants, as
this may harm them.
Never spray water onto the unit or wash the air
conditioner with water.
Never let the air conditioner blow on a heat
source. This could put the flame out and cause
carbon monoxide poisoning.
To avoid any harm to your health, do not blow
the cold air on your body too long or lower the
room temperature too much.
This air conditioner cannot be used for drying
clothes or chilling foods.
Warning:
Do not cut or damage the power cords and
control lines. Any damaged power cords and
signal control lines of the air conditioner must
be replaced by qualified technicians with special
cords.
Persistent abnormality indicates that the air
conditioner may be damaged with the
consequent risk of electric shock or fire. This
may cause an electric shock.
To prevent fire always use a special power
supply circuit.
Disconnect the air conditioner from the power
supply if it is to be left unused for a long period.
For 18-23K, 230V, with a tolerable fluctuation of
±23V. The compressor is subject to strong
vibrations under very low voltages which can
damage the refrigerating system. Electrical
elements are easily damaged by high voltage.
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - PRECAUTIONS FOR USE

25PRECAUTIONS FOR USEWarning:• Make sure to insert the power plug securely.Insecure insertion of the plug may causeelectrocution or fire.• Never unplu

Seite 2 - INSTRUCTIONS FOR USE

Warning:Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause electrocution orfire, so please contact the Whirlpool Autho

Seite 3

35Malfunction CauseWater leaks from outdoorunit.• In cooling mode, water may condense on pipe or pipe joint due tocooling.• Defrost water flows out in

Seite 4 - HOW TO USE THE REMOTE CONTROL

36INSTALLATION SERVICE - PRECAUTIONSON INSTALLATIONImportant Precaution1. The air-conditioning unit must be installedaccording to national wiring rule

Seite 5 - Remote Control

37ELECTRICAL SAFETY REQUIREMENTS1. The power supply must be of rated voltage withspecial circuitry for air-conditioning. Thediameter of the power cord

Seite 6

38INSTALLATION DIMENSION DRAWINGSFrom the ceilingOver 15 cmOver 15 cmOver 15 cmFrom the WallFrom the WallAbove the floorOver 300 cmOver 240 cmAir inta

Seite 7

39INSTALLING INDOOR UNITInstalling Wall-Mount Frame1. Level with plumb line or spirit level. As the drain outlet is on the left side, it is better for

Seite 8 - CLEANING AND MAINTENANCE

Connection of Indoor and Outdoor Cables1. Pull open the front panel;2. Unscrew the screw fastening the covering plate onterminal board. (See Fig. 1);3

Seite 9

41Installing Connecting Pipe1. The tapered end of the connecting pipe must be in line with the corresponding tape face of the valvejoint.2. Tighten th

Seite 10 - TROUBLESHOOTING

42INSTALLING OUTDOOR UNITCable connectionFor AMD 064:1. Remove the handle on the rightside plate of the outdoor unit(one screw).2. Remove the cable cl

Seite 11

43For AMD 065:1. Disassemble the front side plateon the outdoor unit front sideplate (4pc screw).2. Remove the cable clamp,connect the power connectio

Seite 12 - ON INSTALLATION

26• Ensure that the power supply is suitablyprotected by a special circuit with air breaker.The air conditioner automatically starts or stopsaccording

Seite 13

44Installing the pipesInstall the drain fitting and the drain hose (for modelwith heat pump only).Condensation is produced and flows from theoutdoor u

Seite 14

45CHECKS AND TEST RUN AFTERINSTALLATIONCheck Items After InstallationTe s t Ru n1. Preparation of Test Run• Do not switch on the power before all ins

Seite 15 - INSTALLING INDOOR UNIT

27DESCRIPTION OF AIR CONDITIONER1. Terminal board cover plate2. Key switch3. Front panel4. Filter5. Guide louver6. Display7. Wall pipe8. Sealing tape9

Seite 16

28HOW TO USE THE REMOTE CONTROLOperating Guideline - General Procedures1. After the main unit is connected to power, press the ON/OFF keyon the remote

Seite 17

29UP/DOWNUP/DOWN KeyPress these two keys when in COOL, DEHUMIDIFY, FAN or HEAT mode to set a temperature between16 and 30°C. The temperature of each m

Seite 18 - INSTALLING OUTDOOR UNIT

30CLOCKCLOCK keyPress to set present time and then flashes. Press or to adjust the time numeral segmentwithin 5 seconds, if you press this button

Seite 19 - Front side panel

31STORAGE AND TIPS FOR USING THE RCHow to insert the batteries1. Unscrew the screw on the battery cover.2. Gently press down on the battery cover and

Seite 20 - Vacuum pump

32CLEANING AND MAINTENANCEWarning• Make sure to stop the unit and unplug it beforecleaning your air conditioner. Otherwise youmay risk electrocution.•

Seite 21 - INSTALLATION

331. Removing the air filterGrasp the groove on the two ends of the frontpanel. Pull as shown by the arrow with force toopen the front panel at an ang