Location Requirements
You will need:
A location allowing for proper exhaust installation.
See “Venting Requirements.”
A separate 30 amp circuit.
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
A sturdy oor to support the total weight (dryer and load)
of 200 lbs. (90.7 kg). The combined weight of a companion
appliance should also be considered.
Level oor with maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Level
Caulking gun and
compound (for installing
new exhaust vent)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting,
and read “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Mobile home installations require metal exhaust system hardware,
available for purchase from the dealer from whom you purchased
your dryer. For further information, please reference the
“Assistance or Service” section of the Use and Care Guide.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to the
dryer must end in ring terminals or spade terminals with
upturned ends.
A UL listed strain relief.
Parts supplied (all models):
Leveling legs (4)
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed:
Flat-blade screwdriver #2 Phillips screwdriver
Wire stripper
(direct wire installations)
Tin snips
(new vent installations)
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Vent clamps
1/4" nut driver
(recommended)
Utility knife
Tape measure
Pliers