IF THE OUTDOOR UNIT IS INSTALLED
LOWER THAN THE INDOOR UNIT (picture 1)
1. A drain pipe should be above ground and the end of
the pipe does not dip into water. All pipes must be
restrained to the wall by saddles.
2. Taping of the pipe must be done from bottom to
top.
3. All pipes are bound together by tape and restrained
to the wall by saddles.
IF THE OUTDOOR UNIT IS INSTALLED
HIGHER THAN THE INDOOR UNIT (picture 2)
1. Taping should be done from lower to upper part.
2. All pipes are bound and taped together and trapped
the pipes to prevent water returning to the room
(see picture).
3. Restrain all pipes to the wall with saddles.
Sealed
Saddle
Drain pipe
Picture 1
Drain pipe
Refrigerant
pipe
Tape
Wire
Trap
Picture 2