Select the best location
Location for Installing the Indoor Unit
Where there is no obstacle near the air outlet and air can easily be blown
to every corner.
Where piping and wall hole can easily be arranged.
Observe the required distance from ceiling and wall according to the
wiring diagram.
Where the air filter can easily be removed.
Keep the unit and remote control 1 m or more from the television, radio
etc.
The remote controller will operate abnormally in a room fitted with digital
lights.
Do not put anything near the air inlet that could obstruct it.
In a place that can bear the weight and will not increase operating noise
and vibrations.
Location for Installing the Outdoor Unit
Install in a convenient and well-ventilated place; avoid installing it where
flammable gas could leak.
Observe the required distance from the wall.
The pipe is 15 meters in length maximum. If it exceeds 7 meters,
additional refrigerant of 40 grams per meter is needed. The permitted
elevation between indoor and outdoor units is 5 meters. If the outdoor
unit is higher than the indoor one, an elbow in the pipe before entering
indoor side is necessary.
Do not install the outdoor unit in a dirty or greasy place, near a
vulcanization gas exit or highly salty seashore.
Avoid installing it at the roadside where it could be soiled with muddy
water.
A fixed base where operating noise will not increase.
Where the air outlet is not obstructed.
Install where the neighbors will not be annoyed by operating noise or
discharged air.
Outdoor unit installation
1.
Install Drain Port and Drain Hose (for heat-pump model
only)
The condensate drains from the outdoor unit when the unit operates in
heating mode. In order not to disturb your neighbours and protect the
environment, install a drain port and a drain hose to direct the
condensate water. Just install the drain port and rubber washer on the
chassis of the outdoor unit, then connect a drain hose to the port as
shown in the figure on the right.
2.
Install and Fix Outdoor Unit
Fix with bolts and nuts tightly on a flat and strong floor. If installed on
the wall or roof, make sure to fix the support well to prevent it from
shaking due to serious vibrations or strong wind.
3.
Outdoor Unit Piping Connection
Remove the valve caps from the 2-way and 3-way valve. Connect the
pipes to the 2-way and 3-way valves separately according to the
required torque.
4.
Outdoor Unit Cable Connection (see page 38)
Model
Max. Allowable
Tubing Length
at Shipment (m)
Limit of
Tubing
Length (m)
Limit of
Elevation
Difference H (m)
Required
amount of
additional
refrigerant (g/m)
7K, 9K, 12K 5 15 5 25
Indoor unit A
elevation should
be less than 5m
To indoor Unit B
Outdoor unit
elevation should
be less than 5m
Indoor unit A
The
maximum
length of
pipes is 15
meters
Outdoor
unit
Indoor
unit B
Drain port
Drain hose
(prepare by user)
Washer
Curled tube for
returning liquid
33933051GB.fm Page 149 Tuesday, January 18, 2005 3:31 PM