RIGHT END VIEW
WATER INLET ;
SOLENOID
VALVE
I
I
I
I
I
7.112”
1
34-13132
-Lt-
J
BEND FIELD SUPPLIED WATER LINE
TO CONNECT TO WATER VALVE FITTING
l-1/2”
Connect the drain
(observe local codes)
1. The unit is provided with a gravity drain,
2. The ideal installation has a standpipe (1 l/4”
minimum) installed directly below the outlet of the
drain tube. Refer to figure 5 for the proper location
of the standpipe.
3. It may be desirable to insulate drain line thoroughly
up to drain inlet to minimize condensation on drain
tube.
Condensate pump
1. When drain connection below the level of the unit
is not available a condensate pump may be used to
lift the water to an available drain.
2. Install condensate pump on floor behind ice maker
with discharge tube to the rear. Run bin drain directly
into pump as shown in the illustration.
NOTE:
Electric connection to condensate pump
should be from a circuit that remains energiz-
ed continually.
BACK VIEW
FIGURE 5
-17.7/w*-
1
4” LONG 5/8” I.D. RUBBER
DRAIN TUBE - RUN TO
HOLE FOR FIELD
SUPPIED WATER
CONDENSATE PUMP HAS FLOAT
SWITCH THAT CYCLES
ADD PLASTIC HOSE
ITS PUMP. DO NOT
FROM BIN DRAIN
CONNECTTHRU
DIRECTLY TO
MACHINE CONTROLS
/ !i% TUBE
FIELD SUPPLIED
WATER LINE
THRU THIS HOLE.
, .
4