DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance “A” between the wall cabinets is between
600 mm and 680 mm, the height “B” must be a minimum of 520 mm.
if the distance “A” between the wall cabinets is greater than the width
of the hob, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the hob, please refer to the hood
instructions fot the correct distance.
P/B3H2II YROGETACELBAT SROTCEJNI
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Rapid129 B3.00286 l/h0.60
17 20 25Semi-rapid 97 1.65 157 l/h0.35
Auxiliary 74 B1.0095 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Rapid863.00218 g/h0.60
25 30 35
Semi-rapid 65 1.65 120 g/h 0.35
Auxiliary501.0073 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 1 R - 2 SR - 1 AUX 7.30 715 l/h9.52
G30/G31 30 mbar 1 R - 2 SR - 1 AUX 7.30 545 g/h30.94
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz