ENGLISH 14
- tighten screw to reduce the ame height
(-);
- loosen screw to increase the ame height
(+).
The adjustment must be performed with the
tap in minimum gas setting position (small
ame ) .
- The primary air of the burners does not
need to be adjusted.
- At this stage, light up the burners and
turn the knobs from max position
to
minimum position
to check ame
stability.
Upon completion of adjustment, reseal
the work surface using sealing wax or an
equivalent material.