Whirlpool GOW 9553/NB Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
HOW TO USE THE HOB
WARNING
Do not let the burner ame extend beyond the edge of the pan.
IMPORTANT: when the hob is in use, the entire hob area may become hot.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum ame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts o the gas supply to the burner if the ame goes out accidentally (because of sudden draught, an interruption in the gas
delivery, boiling over of liquids, etc.).
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit, wait at least one minute before
trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner dicult, it is advisable to repeat the operation with
the knob turned to small ame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: if the distance “A” between the wall cabinets is
between 600 mm and 730 mm, the height “B” must be a
minimum of 530 mm.
if the distance “A” between the wall cabinets is greater
than the width of the hob, the height “B” must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please
refer to the hood instructions fot the correct distance.
40
min. R 6,5
max. R 8
min 70
510
860
840
0
+2
max 492
min 480
750 min.
50 min.
100
B
B
A
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
LIQUEFIED
PETROLEUM GAS
(Propane) G31
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6W
286 l/h
167 l/h
95 l/h
476 l/h
86 l/h
Rapid
Semi-rapid
Auxiliary
DCC - Outer + Inner
DCC - Inner
130 B
97 A
78 A
155 S4 + 70 H1
70 H1
3,00
1,75
1,00
5,00
0,90
0,60
0,35
0,30
1,90
0,30
Rapid
Semi-rapid
Auxiliary
DCC - Outer + Inner
DCC - Inner
87
66 A
50
100 + 44
44
3,00
1,75
1,00
4,60
0,80
218 g/h
127 g/h
73 g/h
334 g/h
57 g/h
0,60
0,35
0,30
1,90
0,30
0,60
0,35
0,30
2,20
0,30
Rapid
Semi-rapid
Auxiliary
DCC - Outer + Inner
DCC - Inner
87
66 A
50
100 + 44
44
3,00
1,75
1,00
4,60
0,80
218 g/h
127 g/h
73 g/h
334 g/h
58 g/h
17
20
25
20
28-30
37
25
35
45
Total rated
consumption
Rated thermal
owrate (kW)
Model conguration
5 BURNERS
Air required (m) for
burning 1m of gas
Type of gas used
Type of gas
used
Type of burner Injector
marking
kW
min. rat. mx.
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
1 R - 2 SR - 1 AUX - 1DCC
1 R - 2 SR - 1 AUX - 1DCC
1 R - 2 SR - 1 AUX - 1DCC
12,50
12,10
12,10
1190 l/h
880 g/h
864 g/h
9,52
30,94
23,80
INJECTORS TABLE CATEGORY II2H3+
LIQUEFIED
PETROLEUM GAS
(Butane) G30
NATURAL GAS
(Methane) G20
Seitenansicht 5
1 2 3 4 5 6

Kommentare zu diesen Handbüchern