It is best to change the injectors before starting installation. Steps for injector exchange are:
1. Remove the grids and burner/rings/caps and knobs (see APPENDIX A).
2. Remove the holding screws that fix the burner to the top cover.
Use gloves to lift up the cover.
Once you have removed the top cover, you can access the
burner injector.
3. Remove the injector (F) using a 7mm side spanner.
Install new injector according to the table.
4. Slacken the holding screw (H) to regulate the position (X)
of the gas inlet coupling (G) with regard to the injector.
This needs to be done only if coupling (G) was moved –
or dimension (X) is not aligned with the table.
Regulating the minimum flow level of the gas taps
Regulating the minimum flow level must be done with the tap at the
lowest position (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the control
knob and adjust the screws found on the tap as follows (see drawing):
1. Tighten to reduce the height of the flame (–);
2. Slacken to increase the height of the flame (+);
3. With the burners on, rotate the knobs from the maximum to
the minimum position to check the stability of the flame.
Once you have finished regulating, close up the seals again using sealing wax.
REFERENCE TO LOCAL REGULATIONS
Provision for ventilation
The room in which the appliance is installed must have an air supply to current B.S. 5440 - Part 2 standards.
All rooms require a permanent vent in addition to the openable window.
If there are other fuel burning appliances in the same room B.S. 5440 - Part 2 should be consulted to determine the air vent
requirements.
If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room
volume.
Gas Safety Regulations
The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety
regulations. Failure to install appliances correctly may lead to prosecution.
It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in accordance
with the Gas Safety (Installation and Use) Regulations, the Building Regulations issued by the Department of the
Environment and the Building Standard (Scotland) (Consolidation) Regulations, issued by the Scottish Development
Department.
In the G.B., CORGI registered installers work to safe standards of practice.
AFTER-SALES SERVICE
Before calling the After-Sales Service, make sure you can give the following information:
- type of fault or problem;
- exact model (written on the label affixed to the instruction/warranty);
- service number that follows the word SERVICE on the rating plate under the hob and
on the label affixed to instruction/warranty;
- your complete address and phone number.
If any repairs are required, please contact an authorised After-Sales Service, as indicated in
the warranty.
Manufacturer: Whirlpool Europe S.r.l. Viale G. Borghi, 27 21025 Comerio (VA) ITALY
(Apply the label from warranty here)