HOW TO USE THE HOB
WARNING
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
•
•
• After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.This burner safety device shuts off the gas supply to
•
NOTE:
In this case, repeat the operations
described above.
NOTE: if the distance “A” between the wall cabinets is
between 600 mm and 730 mm, the height “B” must be a
minimum of 530 mm.
if the distance “A” between the wall cabinets is greater
than the width of the hob, the height “B” must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please refe
r
to the hood instructions fot the correct distance.
+3H2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Power Burner
138 A
3.50 333 l/h1.55
17 20 25Semi-rapid
95 Z
1.75 167 l/h0.35
Auxiliary
72 X
1.00 95 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Power Burner P 93 3.50 254 g/h1.55
20 28-3035Semi-rapid631.75127 g/h0.35
Auxiliary 50 1.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Power Burner P 93 3.50 250 g/h1.55
25 37 45Semi-rapid631.75125 g/h0.35
Auxiliary 50 1.00 71 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 762 l/h9.52
G30 28-30 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 581 g/h 30.94
G31 37 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 571 g/h23.80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz 0,6W