IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete
enclosure around the recessed portion of the oven.
Grounded electrical supply is required. See “Electrical
Requirements” section.
Electrical supply junction box should be located 3"
(7.6 cm) maximum below the support surface when the
oven is installed in a wall cabinet. A 1" (2.5 cm) minimum
diameter hole should have been drilled in the right rear or
left rear corner of the support surface to pass the appliance
cable through to the junction box.
NOTE: For undercounter installation, it is recommended
that the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall
behind oven, it is recommended that the junction box be
recessed and located in the upper center of the cabinet.
Oven support surface must be solid, level, and ush with
bottom of cabinet cutout.
Floor must be able to support a single oven weight of
154 lbs (70 kg).
Floor must be able to support a double oven weight of
288 lbs (131 kg).
IMPORTANT: To avoid damage to your cabinets, check
with your builder or cabinet supplier to make sure that
the materials used will not discolor, delaminate, or sustain
other damage. This oven has been designed in accordance
with the requirements of UL and CSA International and
complies with the maximum allowable wood cabinet
temperatures of 194°F (90°C).
Location Requirements
Undercounter Installation (With Cooktop Installed Above):
Ovens approved for this type of installation have an approval
label located on the top of the oven. Refer to Cutout Dimensions
For Ovens Installed Under Cooktop (separate sheet).
Product Dimensions – Single Ovens
%
'
(
$
&
*
)
A. 28
³⁄4
" (72.8 cm) max. overall height
B. 28
7
16
" (72.2 cm) max. recessed width
C. 26
³⁄4
" (67.9 cm) recessed height
D. 23
¼
" (59.1 cm) max. recessed depth
E. 30" (76.2 cm) overall width
F. 12" (30.5 cm) from back of control panel to start of strain relief
G. 48" (121.9 cm) exible conduit length
Seitenansicht 2