AIR HANDLER INSTALLATION INSTRUCTIONS
AIR HANDLER SAFETY
INSTALLATION REQUIREMENTS
These instructions are intended as a general guide only and do
not supersede any national or local codes in any way.
Compliance with all local, state, or national codes pertaining to
this type of equipment should be determined prior to installation.
Read this entire instruction manual, as well as the instructions
supplied in separate equipment, before starting the installation.
All models are designed for indoor installation only.
The installation of the air handler, field wiring, warm air ducts, etc.
must conform to the requirements of the National Electrical
Code, ANSI/NFPA No. 70 (latest edition) in the United States, and
any state laws, and local ordinances (including plumbing or
wastewater codes). Local authorities having jurisdiction should
be consulted before installation is made. Such applicable
regulations or requirements take precedence over the general
instructions in this manual.
Table of Contents
AIR HANDLER SAFETY .................................................................1
INSTALLATION REQUIREMENTS................................................1
Tools and Parts ............................................................................2
Location Requirements................................................................2
Installation Configurations ...........................................................3
Electrical Requirements ...............................................................3
Ductwork Requirements ..............................................................4
INSTALLATION INSTRUCTIONS..................................................4
Inspect Shipment .........................................................................4
Install Ductwork............................................................................4
Install Filter....................................................................................4
Make Electrical Connections .......................................................5
Complete Installation....................................................................7
SEQUENCE OF OPERATION ......................................................10
AIR HANDLER MAINTENANCE ..................................................10
ASSISTANCE OR SERVICE.........................................................10
Accessories ................................................................................10
WARRANTY ..................................................................................11
Whirlpool
©
Model WMB
0650329-60
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - INSTALLATION REQUIREMENTS

AIR HANDLER INSTALLATION INSTRUCTIONSAIR HANDLER SAFETYINSTALLATION REQUIREMENTSThese instructions are intended as a general guide only and do not sup

Seite 2 - Location Requirements

10SEQUENCE OF OPERATIONCooling (cooling only or heat pump)When the thermostat calls for cooling, the circuit between R and G is completed, and the blo

Seite 4 - INSTALLATION INSTRUCTIONS

Keep this book and your sales slip together for future reference. You must provide proof of purchase or installation date for in-warranty service.Writ

Seite 5 - Make Electrical Connections

2Install the conditioned air plenum, ducts and air filters (not provided) in accordance with NFPA 90B Standard for the Installation of Warm Air Heatin

Seite 6

3Installation ConfigurationsFor ease in installation, it is best to make any necessary coil configuration changes before setting the air handler in pl

Seite 7 - Complete Installation

4Ductwork Requirements Install the conditioned air plenum, ducts and air filters (not provided) in accordance with NFPA 90B Standard for the Installa

Seite 8 - COOLHEATADJUST

5Make Electrical Connections208/240 Volt Installations1. Disconnect all power supplies.2. Remove the blower access panel.3. Route the field supply wir

Seite 9

6Wiring Diagram—Blower (PSC Motor)Wiring Diagram—Optional Electric Heat12345618 BK2418 R18 BUCTRCOM208V240V14 Y L214 BK L124V(H) (H)5312TD **14 R18 B

Seite 10 - ASSISTANCE OR SERVICE

7Wiring Diagram—Blower (Variable Speed Motor) Complete InstallationPre-Start Check Is unit properly located, level, secure, and serviceable? Is the

Seite 11

8To change blower speed: Refer to “Wiring Diagram—Blower (PCS Motor)” and “Wiring Diagram—Optional Electric Heat.”1. Disconnect all power supplies.2.

Seite 12 - Printed in U.S.A

9Blower Performance Chart—Variable Speed MotorThe versatility of the variable speed motor enables the air handler to tailor its performance to the dif